Rheonik Coriolis Flow Transmitters

Whether an end user or a system builder, Rheonik has a transmitter option that will meet your needs.

Depending upon your needs, the process transmitter range has fully featured multi-function units for safe area and hazardous area use or mass flow only units.

System builders and OEM customers will find low cost, small footprint high performance options in our OEM range.

Transmitter Model Overview

The process transmitter range consists of rack and field mounting units for both general purpose and hazardous area use.

RHE08 Transmitter

RHE08

The RHE08 transmitter is designed for field mounting. With a weatherproof exterior, the RHE08 can be wall or panel-front mounted. The UV resistant display window will not crack, craze or cloud over time. Externally mounted buttons provide convenient operator access to all process variables and setup information. Cable entries are adaptable for flex, armored cable or conduit and all terminations are accessible through a separate cover plate.

The RHE08 is a multi-function transmitter that measures flow, density and temperature simultaneously and can be configured to a variety of SI and ANSI units of measurement. Process specific functions include °Brix, normalized gas volume and solids concentration.

The RHE08 transmitter can be used with any RHM sensor in a Class 1, Div. 1 area (RHE08 must be mounted in an ordinary or Class 1, Div. 2 area).

RHE12

The RHE12 hazardous area transmitter is designed for field mounting in hazardous areas. The RHE12 provides accurate and reliable display of mass flow and temperature only and is an ideal, low cost unit for in-plant general process flow measurement. The transmitter is configured and operated through-glass with a magnetic wand or through the SensCom Coriolis meter transmitter software package. Cable entries are adaptable for flex, armored cable or conduit. HART communications is provided as standard.

The RHE12 can be configured to both SI and ANSI units of mass measurement.

The RHE12 transmitter can be used with any RHM sensor in a hazardous area.

RHE12 Coriolis Meter
RHE26 Transmitter

RHE26

The RHE26 transmitter is designed as a low cost, minimal footprint, panel mounted flow transmitter. For OEM installations, an optional accessory is also available to adapt the RHE26 for DIN rail mounting inside a panel or enclosure. Power supply is 12 – 24Vdc. The user interface consists of a high clarity color display and three pushbuttons operating an intuitive menu system. Cable connection is through convenient pluggable headers on the back panel of the instrument.

The unit provides a front panel USB port for connection of the RHECom software package. RHECom is available for download at no cost from the Rheonik website. The unit can be configured to display mass flow, volumetric flow, density and temperature. It also has a comprehensive set of forward, reverse and net totalizers. Units of measurement can be selected from a wide variety of both ANSI and SI units. Fully featured Modbus over RS485 is included as standard.

The RHE26 is available with the Assurance Factor and Assurance View advanced diagnostics. Assurance Factor provides a single value measurement confidence factor while Assurance View allows review of a multitude of diagnostics indicators. Screen color changes depending upon Assurance Factor value, giving real time indication for measurement confidence.

The RHE26 transmitter can be used with an RHM sensor in a hazardous area (RHE26 in safe area).

RHE27

The RHE27 transmitter is a fully featured panel mounted flow transmitter. Power supply options are AC power, DC power or both, where DC can be a battery and act as backup power if the AC goes out. The user interface consists of a high clarity color display and three pushbuttons operating an intuitive menu system. Cable connection is through convenient pluggable headers on the back panel of the instrument. A wide variety of I/O options are available, including double pulse outputs and analog input for pressure corrections.

The unit provides a front panel USB port for connection of the RHECom software package. RHECom is available for download at no cost from the Rheonik website. The unit can be configured to display mass flow, volumetric flow, density and temperature. It also has a comprehensive set of forward, reverse and net totalizers. Units of measurement can be selected from a wide variety of both ANSI and SI units. Fully featured Modbus over RS485 is included as standard.

Process specific features such as corrected volume to API standards, net oil calculation and standardized gas volume are available. These features remove the need for additional flow computer equipment to provide a low cost solution where such requirements are needed.

The RHE27 is available with the Assurance Factor and Assurance View advanced diagnostics. Assurance Factor provides a single value measurement confidence factor while Assurance View allows review of a multitude of diagnostics indicators. Screen color changes depending upon Assurance Factor value, giving real time indication for measurement confidence.

The RHE27 transmitter can be used with an RHM sensor in a hazardous area (RHE27 in safe area).

RHE27 Transmitter

OEM Transmitter Range Overview

OEM transmitters are designed to provide low cost, high accuracy flow measurement options for system builders and integrators where space is at a premium.

RHE14

The RHE14 provides the accurate measurement of mass flow and temperature only and is an ideal, low cost unit for industrial equipment manufacturers. The transmitter is configured and operated exclusively through the SensCom Coriolis meter transmitter software package. The RHE14 can be configured to both SI and ANSI units of mass measurement.

A safety barrier support module is available to allow the RHE14 to be connected to an RHM sensor in a hazardous area and the RHE15 Profibus module can be directly connected for further connectivity.

RHE14 Transmitter
EZB Safety Barrier Module
RHE15 Profibus Module
RHE16 Transmitter
RHE16 Compact Transmitter

RHE16

The RHE16 transmitter is a multi-function transmitter that measures flow, density and temperature simultaneously and can be configured to a variety of SI and ANSI units of measurement. It provides added functionality over the RHE14 for users who want to be able to measure volumetric flow and density in addition to mass flow. Communications is through Modbus over a robust RS485 serial connection.

As an additional convenience, the RHE16 can be compact mounted directly on any RHM sensor. The RHE16 is configured and operated through the RHECom software package through a USB connection or over the RS485 serial connection. RHECom is available for download at no cost from the Rheonik website. A fully detailed Modbus register set allows developers to read and write all parameters to and from the transmitter.