EXtract Pneumatically Operated Retractable Housings for Ø12mm Sensors and Electrodes

EXtract 810 – for Flange, NPT and Triclamp Mount

Pneumatically operated retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes. Features insertion length of 107mm (4.2”) and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 225mm gel filled and Ø12 x 280mm liquid filled sensors with PG13.5 thread
  • Max pressure 16 bar / 232 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in 316L stainless steel or alloy C22
  • Process connections:
    • DIN PN16 flanges – DN32, DN40, DN50
    • ANSI 150# flanges – 1¼, 1½, 2”
    • Triclamp – 1/1½”, 2”
    • Male 1¼” NPT thread
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Requires 4 – 6 bar (58 – 87 psi) air supply for operation

EXtract 811 – Extended Insertion Flange Mount

Pneumatically operated retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes. Features insertion length of 207mm (8.15”) ”) for longer probes/reach and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 325mm gel filled and Ø12 x 380mm liquid filled sensors with PG13.5 thread
  • Max pressure 16 bar / 232 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in 316L stainless steel or alloy C22
  • Process connections:
    • DIN PN16 flanges – DN40, DN50
    • ANSI 150# flanges – 1½, 2”
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Requires 4 – 6 bar (58 – 87 psi) air supply for operation

Extract 815 – for Ingold DN25 Ports

Pneumatically operated retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes through Ingold DN25 (G1¼“ thread) ports. Features insertion length of 90mm (3.5”) and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 225mm gel filled and Ø12 x 280mm liquid filled sensors with PG13.5 thread
  • Max pressure 16 bar / 232 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in 316L stainless steel or alloy C22
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Requires 4 – 6 bar (58 – 87 psi) air supply for operation

EXtract 820 – (Plastic) Flange and NPT Mount

Pneumatically operated retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes. Features insertion length of 94mm (3.7”) and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 225mm gel filled and Ø12 x 280mm liquid filled sensors with PG13.5 thread
  • Max pressure 10 bar / 145 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in Polypropylene (PP), PVDF/Alloy C22 and PEEK
  • Process connections:
    • DIN DN50 PN16 flange
    • 2” ANSI 150# flange
    • Male 1¼” NPT thread
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Requires 4 – 6 bar (58 – 87 psi) air supply for operation

EXtract 821 – (Plastic) Extended Insertion Flange Mount

Pneumatically operated retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes. Features insertion length of 194mm (3.7”) ”) for longer probes/reach and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 325mm gel filled and Ø12 x 380mm liquid filled sensors with PG13.5 thread
  • Max pressure 10 bar / 145 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in PVDF/alloy C22 and PEEK
  • Process connections:
    • DIN DN50 PN16 flange
    • 2” ANSI 150# flange
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Requires 4 – 6 bar (58 – 87 psi) air supply for operation

EXtract 830 – Hygienic EHEDG/3A Housing

Pneumatically operated retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes through a wide variety of different process connections.

  • Accommodates Ø12 x 225mm gel filled and Ø12 x 280mm liquid filled sensors with PG13.5 thread
  • Max pressure 10 bar / 145 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • 316L stainless steel
  • Surface finish of Ra<0.78μm / 30μinch, electropolished
  • Process connections:
  • Ingold DN25 / G1¼”
  • Ingold HyCIP® DN25 / G1¼”
  • Varivent N DN40-125
  • Triclamp – 1/1½”, 2”
  • NEUMO BioControl D50
  • DIN 11851 DN50 (dairy connection)
  • Cleaning ports
  • G threads – ⅛”, ¼”
  • ¼” female NPT thread
  • ¼” Triclamp
  • Process seal options of EPDM (FDA / USP VI) or FPM (Viton™)
  • Requires 4 – 6 bar (58 – 87 psi) air supply for operation

EXconnect 150 – pneumatic hose connection kit for EXtract housings

EXconnect provides a convenient tube bundle in various lengths for simple connectivity to Extract sensor and electrode housings. Each EXconnect kit contains air tubes color ands size coded for quick and easy connection to a housing plus includes optional tubes for vale operation

  • Supplied as 3, 5 or 10m (118”, 197” or 394”) multi-tube bundles for connection to retractable housing
  • Add up to three optional tubes to connect to local cleaning valves, etc.

EXtract Technical Data Sheet

Need more information? Download detailed technical data sheet here.

Looking for More Information?

Contact Us Today for More Specific Information