EXtract-M Manually Operated Retractable Housings for Ø12mm Sensors and Electrodes

EXtract 810M – for Flange, NPT and Triclamp Mount

Manually retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes. Features insertion length of 107mm (4.2”) and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 225mm gel filled and Ø12 x 280mm liquid filled sensors with PG13.5 thread
  • Max pressure 16 bar / 232 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in 316L stainless steel or alloy C22
  • Process connections:
    • DIN PN16 flanges – DN32, DN40, DN50
    • ANSI 150# flanges – 1¼, 1½, 2”
    • Triclamp – 1/1½”, 2”
    • Male 1¼” NPT thread
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Optional position switches available

EXtract 811M Extended Insertion Flange Mount

Manually retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes. Features extended insertion length of 207mm (8.15”) for longer probes/reach and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 325mm gel filled and Ø12 x 380mm liquid filled sensors with PG13.5 thread
  • Max pressure 16 bar / 232 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in 316L stainless steel or alloy C22
  • Process connections:
    • DIN PN16 flanges – DN40, DN50
    • ANSI 150# flanges – 1½, 2”
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Optional position switches available
EXtract 811m
EXtract 811

Extract 815M – for Ingold DN25 Ports

Manually retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes through Ingold DN25 (G1¼“ thread) ports. Features insertion length of 90mm (3.5”) and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 225mm gel filled and Ø12 x 280mm liquid filled sensors with PG13.5 thread
  • Max pressure 16 bar / 232 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in 316L stainless steel or alloy C22
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Optional position switches available

EXtract 820M – (Plastic) Flange and NPT Mount

Manually retractable sensor housing in plastic for installation of Ø12mm sensors and electrodes into tanks and pipes. Features insertion length of 94mm (3.7”) and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 225mm gel filled and Ø12 x 280mm liquid filled sensors with PG13.5 thread
  • Max pressure 10 bar / 145 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in Polypropylene (PP), PVDF/Alloy C22 and PEEK
  • Process connections:
    • DIN DN50 PN16 flange
    • 2” ANSI 150# flange
    • Male 1¼” NPT thread
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Optional position switches available

EXtract 821M – (Plastic) Extended Insertion Flange Mount

Manually retractable sensor housing in plastic for installation of Ø12mm sensors and electrodes into tanks and pipes. Features insertion length of 194mm (3.7”) ”) for longer probes/reach and integrated scraper to remove process build up when operated.

  • Accommodates Ø12 x 325mm gel filled and Ø12 x 380mm liquid filled sensors with PG13.5 thread
  • Max pressure 10 bar / 145 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • Available in PVDF/alloy C22 and PEEK
  • Process connections:
    • DIN DN50 PN16 flange
    • 2” ANSI 150# flange
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)
  • Optional position switches available

EXtract 830M – Hygienic EHEDG/3A Housing

Manually retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes through a wide variety of different process connections.

  • Accommodates Ø12 x 225mm gel filled and Ø12 x 280mm liquid filled sensors with PG13.5 thread
  • Max pressure 10 bar / 145 psi
  • Operating temperature -10°C / 14°F to 140°C / 285°F
  • 316L stainless steel
  • Surface finish of Ra<0.78μm / 30μinch, electropolished
  • Process connections:
    • Ingold DN25 / G1¼”
    • Ingold HyCIP® DN25 / G1¼”
    • Varivent N DN40-125
    • Triclamp – 1/1½”, 2”
    • NEUMO BioControl D50
    • DIN 11851 DN50 (dairy connection)
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
    • ¼” Triclamp
  • Process seal options of EPDM (FDA / USP VI) or FPM (Viton™)
  • Optional position switches available

EXtract 840M – Long Insertion Length Housing

Manually retractable sensor housing for installation of Ø12mm sensors and electrodes into tanks and pipes. Features user adjustable insertion length of up to 700mm (27.5”) and patented high pressure safety bayonet lock.

  • Accommodates Ø12 x 120mm gel filled sensor with PG13.5 thread
  • Max pressure 12 bar / 174 psi
  • Operating temperature -10°C / 14°F to 130°C / 266°F
  • 316L stainless steel
  • Optional isolating ball valve
  • Process connections:
    • DIN DN32 PN16 flange
    • 1¼” ANSI 150# flange
    • Male or female 1¼” NPT thread
  • Cleaning ports
    • G threads – ⅛”, ¼”
    • ¼” female NPT thread
  • Process seal options of EPDM (FDA / USP VI), FPM (Viton™) or FFKM (Kalrez™)